Click to enlarge image

 Model Number YSA-20A

Feature

  • Amplifier to convert strain gage signal from load cell to DC voltage.
  • Multi-step filter integrated.
  • Automatic temperature compensated by calibration circuit.
  • 0.8%FS accuracy
  • Auto zero set by Push Button.
  • Function control by rotary s/w.
  • Response frequence : DC~20KHz(-3dB)
    *option : 100KHz, 200KHz, 300KHz, 500KHz, 800KHz

This amplifier, with integrated microprocessor, converts resistance differences to DC voltage and is widely used for various sensors like a strain gage type load cell.

SPECIFICATIONS
Number of measuring point
1Point per each unit
Measuring method
Deflection method
Application gage resistance
100Ω~1KΩ
Measuring range 10V-1mV~20mV/V, 5V-2mV~40mV/V, 2.5V-4mV~80mV/V
Bridge voltage(BV/V)
Constant voltage, DC 5V, 10V
Zero set range Adjustment by 10 turns VR(10%)
Output 0~±10VDC(load resistance≥2kΩ),4mA~20mA(load resistance<500Ω)
Nonlinearity ±0.02% F.S
Sensitivity adjustment 1000multiplier
S/N ratio 51dB
Low pass filter 10Hz, 100Hz, 1KHz, 10KHz
Operating Temperature -10°C~60°C
Temperature sensitivity ±0.03% F.S./°C
Calibration 0.5mV/V=1000µ STRAIN
Power sensitivity ±5%
Display 3 1/2 DIGIT
Size 45.5(W)x129(H)x234(D)mm
Power AC 110V/220V, 50~60Hz

 