Click to enlarge image
|
Model Number |
TCL-A 0.2% |
|
TYPE
|
STROKE
|
WEIGHT
|
|
TCL - 30 A
|
30mm
|
250g
|
|
TCL - 50 A
|
50mm
|
280g
|
|
TCL - 100 A
|
100mm
|
330g
|
|
TCL - 200A
|
200mm
|
630g
|
|
TCL - 300A
|
300mm
|
2.5Kg
|
|
|
This linear scale LVDT provides minimal functional error and high acuracy measurement. Operating ranges are 30mm to 300mm
| SPECIFICATIONS |
Rated capacity
|
30mm ~ 300mm |
|
| Temperature range safe |
0°C~60°C |
|
|
|
Excitation recommended
|
4V DC |
|
|
|
|
|
|
|
|
|
|
Terminal resistance input
|
120Ω± 1% |
|
|
Terminal resistance output
|
120Ω± 1% |
|
|
Temperature range compensated
|
0°C~50°C |
|
|
|
|
| DIMENSIONS |
CAPACITY
|
A
|
B
|
C
|
D
|
E
|
F
|
G |
H |
J |
K |
|
30 mm
|
47
|
76
|
129
|
32
|
27
|
27
|
35
|
-
|
6
|
5
|
|
50 mm
|
67
|
96
|
169
|
32
|
27
|
27
|
40
|
-
|
6
|
5
|
|
100 mm
|
117
|
153
|
276
|
32
|
27
|
27
|
70
|
-
|
6
|
5
|
|
200 mm
|
235
|
265
|
505
|
40
|
30
|
28
|
80
|
120
|
6
|
6
|
|
300 mm
|
361
|
361
|
809
|
70
|
45
|
46
|
75
|
254
|
10
|
10
|
|

|
|
|
|
| |
|
|
|